- Hp smart array p410i controller array diagnostics update#
- Hp smart array p410i controller array diagnostics software#
Let the controller discover the new array. Then boot with your old drives and see if they're detected. Go into the BIOS or DL180 setup disk Array Config and delete the RAID 1+0 array. The HP Smart Array utility says there is no RAID controller present.HP SPP doesn't show that any RAID controller is installed either (but it does on the working one). One is working perfectly, but I can't get the RAID controller working on the second one. When you brought up the system with your old drives, you should have again deleted the new data logical drive either in the BIOS raid utility or with the Smartstart/DL180 Setup Array Configuration utility and let the controller detect the array/logical drive. I recently pulled two HP D元60 Gen7 servers out of storage to use for testing. When you went to step #3 in the first drive replacement process Boot up the server and acknowledge errors about failed drives, did you DELETE the removed array/logical drive or just mark it as failed? That's probably the source of the problem here. The removed drives still have the RAID metadata on them. Their recommendation was to recreate the RAID array and restore the data, but that doesn't really help my situation. I have already contacted HP support, and they were unable to help. Is there anything I can do to access the data on the old drives? If not, which RAID controllers support this, so I know what to buy in the future? I can hardly believe that the drives would be rendered inaccessible as soon as they are removed from the original RAID controller. I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case.
Hp smart array p410i controller array diagnostics software#
Software Suite All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility, Array Diagnostic Utility (ADU), and Systems Insight Manager. Then turn system power OFF and move drives to their original positions. HP Smart Array P410 Controller HP Smart Array P410/256 2-ports Int PCIe x8 SAS Controller 462862-B21. Run Array Diagnostics Utility (ADU) if previous positions are unknown. It has a smart array p410i raid with 2 drives in raid-1 configuration. Hp smart array p410i raid and other trusted sources. Insert old drives according to position labels.Īt this point, I get the following error: 1785-Slot 0 Drive Array Not Configured Hp smart array advanced pack 8 hp smart array advanced pack about saap saap is a collection of additional and advanced controller features embedded in the firmware of select smart array controllers.But some data was missed in the last backup, so I need to recover data from the drives in the original array. Format new array and restore data from tape backup.Insert new drives and create new RAID10 array.Boot up the server and acknowledge errors about failed drives.Remove drives used in data array and hot spare, and label with their positions.The old drives would be untouched in case any recovery was needed. The plan was to replace the RAID5 array and hot spare with a RAID10 array composed of much larger disks. This server (our file server) needed an upgrade. The RAID controller is refusing to recognize inserted drives as an array. Please obtain a newer version of the Array Configuration tools to configure or diagnose this controller.I have an HP ProLiant DL180 G5 server with a Smart Array E200 RAID controller. Smart Array P410i in Embedded Slot Critical Controller State: A logical drive was configured with a newer version of the Array Configuration tools than is currently running. Smart Array P410i in Embedded Slot : Device Error Report Report for Smart Array P410i in Embedded Slot These capabilities allow Smart Array controllers to sustain high I/O throughput in a reliable, predictable way.
Please obtain a newer version of the Array Configuration tools to configure or diagnose this controller. Message: Controller State: A logical drive was configured with a newer version of the Array Configuration tools than is currently running.
Hp smart array p410i controller array diagnostics update#
Tenho um Sever ML 350 G6 com uma controlador Smart Array P410i, porem ela nao esta mais aparecendo nao consigo verificar os raid e o SO nao sobe mais, pelo SmartStart ele exibe o seguinte erro para efetuar um update :Ĭontroller: Smart Array P410i in Embedded Slot